UltraBlend Roof Systems

Click each category below to view all available information for that product. Download documents by clicking the icon. Plus, registered users can save files to their favorites or add them to the "Download Queue" for individual or batch download. Not registered yet? It's easy - get started now!


Lap Splice

File Name Size Download
UB-LS-01 Lap Splice with QuickSeam Splice Taper Overlap with EcoWhte QuickSeam at Joint Cover141 kB
UB-LS-02 Lap Splice with Headlap Under Field Seam Using EcoWhite QuickSeam T-Joint Cover139 kB
UB-LS-03 Lap Splice with Headlap Under Curb Or Wall Flashing Using EcoWhite QuickSeam T-Joint Cover160 kB
UB-LS-04 Lap Splice At Curb Or Wall Using EcoWhite QuickSeam T-Joint Covers170 kB
UB-LS-05 Lap Splice with Headlap Under Field Seam Using EcoWhite QuickSeam Flashing149 kB
UB-LS-06 Lap Splice with Headlap Over Field Seam Using EcoWhite QuickSeam T Joint Cover136 kB
UB-LS-07 Seam Edge Treatment Application142 kB
UB-LS-08 LAP SPLICE WITH HEADLAP OVER FIELD SEAM USING ECOWHITE QUICKSEAM FLASHING150 kB
UB-LS-09 Lap Splice with Headlap Under Curb Or Wall Using EcoWhite QuickSeam Flashing169 kB
UB-LS-10 Lap Splice At Field To Curb/Wall Flashing Transition Using EcoWhite T-Joint Cover141 kB
UB-LS-11 Lap Splice At Expansion Joint Tube171 kB

Roof Edge

File Name Size Download
UB-RE-01 Roof Edge Gutter with Flange179 kB
UB-RE-02 Roof Edge with Fascia Metal By Others192 kB
UB-RE-03 Roof Edge with Firestone Una-Edge DE (Drip Edge)188 kB
UB-RE-04 Roof Edge with Firestone Una-Edge GS (Gravel Stop)189 kB
UB-RE-05 Roof Edge with EcoWhite QuickSeam Flashing End Splice Overlap162 kB
UB-RE-06 Roof Edge with EcoWhite QuickSeam Flashing138 kB
UB-RE-07 Roof Edge with EcoWhite QuickSeam Flashing At Field Seam173 kB
UB-RE-08 Roof Edge Splice With QuickSeam Flashing Cover164 kB

Base Tie-In

File Name Size Download
UB-BT-01 Base Tie-In W/Hd Seam Plates Fastened To Deck166 kB
UB-BT-02 Base Tie-In W/Hd Seam Plates Fastened To Wall156 kB
UB-BT-03 Base Tie-In At Curb/Parapet With Existing Cant161 kB
UB-BT-04 Membrane Securement At Outside Corner147 kB
UB-BT-05 Membrane Securement At Inside Corner143 kB
UB-BT-06 Base Tie-In W/Hd Seam Plates – Deck Obstruction167 kB

Corner

File Name Size Download
UB-C-01 Outside Corner157 kB
UB-C-01A Outside Corner – Installation Instuctions154 kB
UB-C-02 Outside Corner At Welded Watertight Curb131 kB
UB-C-02A Outside Corner At Welded Watertight Curb – Steps 1 & 2148 kB
UB-C-02B Outside Corner at Welded Watertight Curb – Step 3 & 4156 kB
UB-C-03 Inside Corner with 3″ Echowhite Splice At Wall Flashing169 kB
UB-C-03A Inside Corner with 3″ Flap And Echowhite Splice Tape Steps 1&2175 kB
UB-C-04 Inside Corner with Separate Wall Flashing162 kB
UB-C-05 Curb Flashing Using 18″ EcoWhite SA Curb Flashing143 kB

Penetration

File Name Size Download
UB-P-01 Penetration with EcoWhite QuickSeam Pipe Flashing208 kB
UB-P-02 Penetration with QuickSeam Conduit Flashing215 kB
UB-P-03 Penetration with Field Fabricated Flashing179 kB
UB-P-04 Penetration (Hot Stack) With Field Fabricated Flashing174 kB
UB-P-05 Penetration with QS6 Penetration Pocket280 kB
UB-P-06 Penetration with Field Fabricated Round PVC Penetration Pocket276 kB
UB-P-07 Penetration with Metal Penetration Pocket To Nailer268 kB
UB-P-08 Penetration with Metal Penetration Pocket To Deck268 kB
UB-P-09 Penetration with Metal Penetration Pocket To Nailer For Recover Or Reroof273 kB
UB-P-10 Membrane Securement At Penetration with HD Seam Plates And Target Patch122 kB
UB-P-11 Membrane Securement At Penetration with HD Seam Plates And Cover Strips152 kB

Drain & Scupper

File Name Size Download
UB-D-01 Roof Drain with Steep Slope Sump175 kB
UB-S-01 Thru-Wall Scupper (Welded Sleeve)191 kB
UB-S-01A Thru-Wall Scupper (Welded Sleeve) Steps 1 & 2185 kB
UB-S-01B Thru-Wall Scupper (Welded Sleeve) Steps 3 & 4168 kB
UB-S-02 Overflow Thru-Wall Scupper (Welded Sleeve)163 kB
UB-S-02A Overflow Thru-Wall Scupper (Welded Sleeve) Steps 1 & 2176 kB
UB-S-02B Overflow Thru-Wall Scupper (Welded Sleeve) Steps 3 & 4164 kB
UB-S-03 Thru-Wall Scupper (Non-Welded Sleeve)193 kB
UB-S-03A Thru-Wall Scupper (Non-Welded Sleeve) Steps 1 & 2180 kB
UB-S-03B Thru-Wall Scupper (Non-Welded Sleeve) Steps 3 & 4189 kB
UB-S-03C Thru-Wall Scupper (Non-Welded Sleeve) Step 5128 kB
UB-S-04 Overflow Thru-Wall Scupper (Non-Welded Sleeve)167 kB
UB-S-04A Overflow Thru-Wall Scupper (No-Welded Sleeve) Steps 1 & 2175 kB
UB-S-04B Overflow Thru-Wall Scupper (No-Welded Sleeve) Steps 3 & 4180 kB
UB-S-04C Overflow Thru-Wall Scupper (No-Welded Sleeve) Step 5129 kB

Termination

File Name Size Download
UB-T-01 Termination with Termination Bar169 kB
UB-T-02 Termination on Outside of Parapet Wall with Termination Bar169 kB
UB-T-03 Termination with Reglet Counterflashing170 kB
UB-T-04 Termination with Reglet and Termination Bar200 kB
UB-T-05 Termination with Surface Mounted Counterflashing181 kB
UB-T-06 Termination with Surface Mounted Counterflashing and Termination Bar207 kB
UB-T-07 Termination At Eifs or Wall Cladding162 kB
UB-T-08 Termination with Bar – Elevation Change179 kB
UB-T-09 Termination at Tilt-Up Wall Joint182 kB
UB-T-10 Termination at Tilt-Up Wall Joint with Reglet Counterflashing206 kB
UB-T-11 Termination at Top of Wall with Coping Stone159 kB
UB-T-12 Termination at Top of Wall with Firestone Coping167 kB
UB-T-12A Termination at Top of Wall Una-Edge Coping160 kB
UB-T-13 Termination at Top of Wall with Firestone AnchorGard Standard142 kB
UB-T-14 Termination at RTU (Unit Flange Above Membrane)165 kB
UB-T-15 Termination at RTU with Counterflashing (Unit Flange Above Membrane)201 kB
UB-T-16 Termination at RTU with QuickSeam Splice Tape (Unit Flange Mounted To Substrate)157 kB
UB-T-17 Termination at RTU with QuickSeam Splice Tape And Counterflashing (Unit Flange Mounted To Substrate)192 kB
UB-T-18 Termination at Shingles133 kB
UB-T-19 Termination at Metal Roof Panel121 kB
UB-T-20 Intermediate Wall Flashing Attachment with QuickSeam Tape and Batten Strip162 kB
UB-T-21 Intermediate Wall Flashing Attachment with QuickSeam Batten Cover173 kB